ASTM D1894 and ISO 8295: Coefficient of Friction on Plastic Film

To ensure that plastic films perform as expected for the end user, the frictional properties of these films must be characterized and controlled.

ASTM D1894 and ISO 8295 are standardized test methods used for determining static (μ_s) and kinetic (μ_k) coefficients of friction of plastic film and sheeting. Plastic film is a widely used material in the packaging industry and includes many types of food packaging (produce bags, carton liners, meat seal wrap) and non-food packaging (envelope liners, potting soil sacks). Plastic films are also key components of more complex products, such as electric vehicle batteries.

This test requires the use of Instron's 2810-005 coefficient of friction fixture, which is specifically designed to meet the requirements of ASTM D1894 and ISO 8295. The film under test is secured on a flat surface, and a sled of known weight is wrapped in the same material. The motion of the crosshead drags the sled along the film being tested, and the force measured is used to determine both the static and kinetic coefficients of friction.

Learn more about:

Related Video(s)

AT3 Automated Film Tensile Testing to ASTM D882

The Instron® TestMaster AT3 Automated Testing System uses an innovative three-axis design for automatic tensile testing of thin films. Normal tensile testing of thin films can prove challenging, but the versatile AT3 makes it easy, improving repeatability, safety, and efficiency by automating everything from measurement to specimen handling and removal.

AT3 Automated Testing System: Configured for Thin Film Testing

The Instron® AT3 Automated Testing System uses an innovative and adaptable design for testing materials such as rigid plastics, elastomers, rubber, thin film, foam, and metals. In this video, the AT3 is testing separator film for electric vehicle batteries. Normal tensile testing of films can prove challenging, but the versatile AT3 makes it easy, improving repeatability, safety, and efficiency by automating everything from measurement to specimen handling and removal. With a smaller footprint than the AT6 robotic system, the AT3 provides a simple and compact solution while still maintaining high throughput and accuracy.

Precision Specimen Loader for Thin Films and Foils

The precision specimen loader improves alignment and the setup process for testing thin films and foils, resulting in reduced variation in test results and improved safety and ergonomics. Available for our 250 N pneumatic side action tensile grips (catalog no. 2712-052), this device uses a detachable alignment clip and linear rail to guide the specimens into the grips. The precision specimen loader is available in multiple sizes to accommodate a wide range of specimen dimensions.