瀏覽 Instron 影片庫,查看測試系統、配件和軟體的實際應用——從產品演示和安裝逐步說明,到客戶案例研究以及材料測試最佳實踐的專家網路研討會。
符合 ISO 11040 與 ISO 7886 標準的注射器測試權威指南
在製藥產業中,機械測試主要由初級包裝容器和組合產品組成。到目前為止,最常見的應用是注射器所需的測試。雖然設計簡單,但對於初次接觸此類評估的實驗室來說,所需的功能和可用性測試數量可能多到令人不知所措。本權威指南旨在確定評估注射器性能的關鍵指標、國際上遵循的最常見標準,以及適用於各種注射器類型的理想夾具。
Instron® | 9400 系列落錘衝擊試驗機
9400 系列落錘衝擊試驗機提供多種容量規格,最高衝擊速度可達 24 m/s,具備卓越性能,並提供無與倫比的精確度和可靠性。該設備可執行各種衝擊試驗方法,包括穿刺、衝擊後壓縮、拉伸、三點彎曲、黏著剝離、緩衝及組件試驗。9400 系列為各種試驗需求提供極致靈活性。
Compression After Impact with a Drop Weight Impact Testing Machine
A CAI test (compression after impact test) is a two-step procedure that assesses the potential damage to composite materials. The CAI test procedure is described in the dedicated standards ASTM D7136M, ASTM D7136, ISO 18352 and Airbus AITM 1.0010. The first step involves using a drop weight impact machine to induce Barely Visible Impact Damage (BVID). This is followed by a compression test of the damaged coupon using an electromechanical machine.
AVE 2 Non-Contacting Video Extensometer
The AVE 2 advanced video extensometer is one of the fastest, most accurate non-contacting strain measurement device commercially available. Utilizing patented measurement technology, this fully-integrated device easily adapts to the normal fluctuations of environmental conditions in your lab including thermal and lighting variations.
ISO 7886-1 Testing Sterile Hypodermic Syringes
ISO 7886 is a testing standard that regulates the mechanical properties of hypodermic syringes and outlines the specifications for single use hypodermic syringes. This video provides a brief overview of annexes D and E, which must be performed on universal testing machines.
AT2 Automated XY Stage: Throughput and Efficiency
For labs stretched thin by a limited number of operators or increased workloads, the AT2 Automated XY Stage is designed to improve throughput and repeatability, while also freeing up your operators to focus on other value add tasks.
Specimen Protect: 6800 and 5900 Series Universal Testing Systems
Specimen Protect is a feature of Instron® 6800 and 5900 Series universal testing systems and system retrofits that limits unwanted forces applied to the specimen during loading. When Specimen Protect is enabled, the actuator or crosshead moves automatically to ensure the force on the specimen remains within the pre-set bounds. It is often used to protect specimens or components during set-up, prior to setting operational limits.
Residual Seal Force Testing with the AT2 Automated XY Stage
Glass vials must maintain a robust seal between the glass vial and the elastomeric closure to prevent product contamination and leakage. Residual seal force (RSF) testing is an evaluation of the quality of this seal. To perform this test, a compression load is applied around the edge of a vial until the lower lip of the aluminum cap breaks away and begins to move in a direction opposite to the loading.