CEAST TUP Calibrations

CEAST TUP Calibrations

Instron professional services are now accredited to carry out on-site NVLAP calibrations for gauged TUPs under 100kN. This calibration can be carried out on your machine thus minimising the amount of time your equipment is down and enabling you to be back up and testing in only a few hours.

Scaricamento

Services 05/07/2020 969.86 KB

Expansion Channel Module

Expansion Channel Module

The Expansion Channel Module (catalog no. 2210-920) allows 6800 and 5900 Series electromechanical testing systems users to add up to eight channels of signal conditioning and control. The expansion module provides up to a total of 13 transducers for simultaneous monitoring, feedback, and control.

Scaricamento

Prodotti 04/30/2020 731.36 KB

250 kN Flexure Fixture Data Sheet

250 kN Flexure Fixture Data Sheet

The 250 kN flexure fixture (catalog no. 2810-206) allows a variety of flexural and fracture toughness bend tests to be performed, including determination of flexural modulus, flexural strength and flexural yield strength. Easy-to-install, the three-point fixture can be modified with an optional conversion kit to provide a four point bending conversion.

Scaricamento

Prodotti 04/29/2020 990.9 KB

Debris Shield Single Column Table Model

Debris Shield Single Column Table Model

To protect operators without harming usability, Instron has developed new shields for tabletop and single column systems.

Scaricamento

Prodotti 04/28/2020 1.59 MB

Traceability Module Data Sheet

Traceability Module Data Sheet

Bluehill Universal’s Traceability Module enables users to meet the audit requirements associated with FDA 21 CFR Part 11, ISO 17025, NADCAP, A2LA, and other accrediting bodies. Through seamless integration of electronic signatures and approvals, file revision history, and an automated, secure audit trail, this powerful add-on provides unmatched data traceability.

Scaricamento

Prodotti 04/09/2020 1.51 MB

Digital I/O Board Guide

Digital I/O Board Guide

The digital I/O board is an optional card which can be added to 5900 and 6800 frames. Digital communication, unlike analog, does not sense continuous signals but inputs or outputs of one of two states: high or low, open or closed. The card used in conjunction with the frame and Bluehill software allows the operator to trigger external or internal events. It allows for 4 input and output channels to be monitored and/or triggered simultaneously.

Scaricamento

Prodotti 04/01/2020 475.75 KB

Drop Tower impact testing for CAI

Drop Tower impact testing for CAI

To properly understand the performance of Composites, one of the most broadly used methods is the CAI (Compression After Impact) test. Low energy impacts can be considered the most dangerous since the damage they cause can be complex and affect all plies of the structure from matrix and fiber crack to delamination. To ensure a level of high quality and compliance with safety standards, impact testing is a key in gathering knowledge as to how these materials behave and may be damaged when impacted.

Scaricamento

Prodotti 03/17/2020 532.13 KB

Brochure sui sistemi di test Premier serie 6800

Brochure sui sistemi di test Premier serie 6800

I sistemi di prova universali Instron serie 6800 offrono precisione e affidabilità senza pari. Basati su un’architettura brevettata Operator Protect con un nuovissimo kit pneumatico Smart-Close e funzionalità di mitigazione delle collisioni, la serie 6800 rende le prove sui materiali più semplici, intelligenti e sicure che mai.

Scaricamento

Prodotti 02/10/2020 3.7 MB

Manuale di Preinstallazione per 34SC-05 modello da tavolo a Colonna Singola

Manuale di Preinstallazione per 34SC-05 modello da tavolo a Colonna Singola

Il Manuale di preinstallazione descrive in dettaglio i requisiti di alimentazione del macchinario e le predisposizioni che il laboratorio deve avere per il funzionamento, i disegni dimensionali, le istruzioni di sollevamento e movimentazione, la procedura di installazione e i dettagli di manutenzione preventiva.

Scaricamento

Manuale 02/24/2020 1.12 MB

Manuale di Preinstallazione per 34TM-50 modello da tavolo a Colonna Doppia

Manuale di Preinstallazione per 34TM-50 modello da tavolo a Colonna Doppia

Il Manuale di preinstallazione descrive in dettaglio i requisiti di alimentazione del macchinario e le predisposizioni che il laboratorio deve avere per il funzionamento, i disegni dimensionali, le istruzioni di sollevamento e movimentazione, la procedura di installazione e i dettagli di manutenzione preventiva.

Scaricamento

Manuale 02/24/2020 1.22 MB