Testing Accessories
- Acessórios para teste de bateria de veículos elétricos
- Dispositivos de alinhamento
- Application Specific Fixtures
- Acessórios para alimentos
- Puncture Probe Set
- Puncture Probe Set, Magness-Taylor
- 3-Jaw Chuck
- Food Fixture Support Frame
- Food Fixture Drip Tray
- Sample Support Plate Set
- Compression Anvil, 2580 mm (4 in) Square Area
- Flat Shear Blade
- Ball-End Probes, Set of 5
- Paper and board
- Biomedical Systems and Accessories
- Acoplamentos e adaptadores
- Acessórios de simulação de colisão
- 2-Piece Sled
- Camera Outriggers
- Low Speed Rear Impact Simulation
- Pitching
- Quick Clamping System for Test-Setup-Pallets
- Side and Pole Impact Simulation
- Custom Accessories
- Dispositivos de teste para compósitos
- Câmaras ambientais e fornos
- Extensômetros
- AVE 2 Non-Contacting Video Extensometer
- Extensômetro de vídeo avançado AVE3
- Extensômetro de média com clipe
- Axial Clip-on
- Biaxial Clip-on
- Biaxial Extensometer 25 mm Axial Gauge Length 1 Axial 1 Transverse
- Biaxial Extensometer 50 mm Axial Gauge Length
- Biaxial Extensometer 1 inch Gauge Length
- Biaxial Extensometer 2 Inch Axial Gauge Length 1 Axial 1 Transverse
- Biaxial Extensometer 25 mm Axial Gauge Length 2 Axial 1 Transverse
- Biaxial Extensometer 50 mm Gauge Length
- Compression Deflectometers (LVDT)
- Medidores de deslocamento de abertura de trinca (COD)
- Extensômetro de longo curso
- Transverse Clip-on Extensometers
- Dispositivos de fixação
- Luminárias flexíveis
- 3 and 4 Point Fatigue Flexure Fixtures
- Flexure Fixture, Fatigue 3 Point
- Flexure Fixture, Fatigue 3 Point
- Flexure Fixture, Fatigue 3 Point
- 20 KN Fixação de curvatura de 3 e 4 pontos
- 3-Point and 4-Point Bend Fixture
- Dispositivos de Teste de Flexão em Três Pontos
- Garras, dispositivos, braçadeiras, faces de mordentes, acoplamentos e adaptadores
- Garras de Ação de Cunha Hidráulicas Avançadas
- Compact Tension Fixtures for Fracture Mechanics
- Compact Tension Fixtures for 50mm Wide Compact Tension Specimens
- Compact Tension Fixtures for 12.5mm Thick Compact Tension Specimens
- Compact Tension Fixtures for 25 mm Thick Compact Tension Specimens
- Additional Extension Rod 2780-120
- Elasticated Fabric
- Hydraulic Wedge Action Grips
- Hydraulic Wedge Action Grips 300kN (67,500 lbf)
- Hydraulic Wedge Action Grips 2000kN (450,000 lbf)
- Hydraulic Wedge Action Grips 1500kN (337,500 lbf)
- Hydraulic Wedge Action Grips 1000 kN (225,000 lbf)
- Hydraulic Wedge Action Grips 600kN (135,000 lbf)
- Mechanical – Wedge Grips
- Mechanical Wedge Lever Action Grips
- Lever Action, Mechanical Wedge Grips; Capacity: 150 kN
- Lever Action, Mechanical Wedge Grips; Capacity: 100 kN
- 150 kN Lever Action Mechanical Wedge Grips
- Microelectronics Tensile Grips
- Pneumatic Lead Pull Grip. Rated capacity: 500 N
- Micro Pneumatic Grips, Side Action. Rated capacity: 10 N
- O Ring Fixtures
- Pneumatic Cord and Yarn Tensile Grips
- Pneumatic/Hydraulic Power Supplies
- Pneumatic Wedge Action Grips
- Pneumatic Wedge Grips
- 2742-103 | ±1 kN Pneumatic Fatigue-Rated Wedge Action Grips
- 2742-205
- 2742-315 ±10 kN ±100 Nm Pneumatic Fatigue Grips
- Torsion and Axial-Torsion Grips
- Axial-Torsion Wedge Grips
- Chuck Style
- Collet Style
- Large Collet Grip Assembly, Range 6.3 – 14.25 mm (0.25 in – 0.5625 in)
- Small Collet Grip Assembly, Range 0.8 – 6.3 mm (0.03125 – 0.25 in)
- Socket Style
- Garras de tração para fios e cabos
- Células de carga
- Dynamic Fatigue
- Static load cells
- 2519 Series S-beam Static Load Cells
- Células de Carga estáticas da Series 2530
- 2580 Series Static Load Cells
- Células de torção
- Acessórios de quadro
- Hydraulic Grip Pump
- 8800 Series Servohydraulic Test Systems
- Air Cushion Isolators
- Air Cushion Isolators (for frames 3 & 4); Not Suitable for 8801 or 8516; Suitable for Testing Frequencies Above 15Hz
- Isolation Mounts for 8801 or 8516 (1 set); For Testing Frequencies Above 15Hz.
- 8800 Series
- Strain Conditioner for 8800MT Series (Control and Data Aquisition)
- Strain Conditioner for 8800MT Series (Data aquisition only)
- Hydraulic Grip Controls
- Air Kits for Pneumatic Grips
- Bombas de garras hidráulicas
- Electromechanical Frame Accessories
- Electropuls All-Electric Dynamic Test Systems
- Safety Guard for ElectroPuls E1000 Test Instrument
- Safety Guard for ElectroPuls E10000 Test Instrument
- Safety Guard for ElectroPuls E3000 Test Instrument
- Safety Guard for ElectroPuls E20000 Test Instrument
- High Stiffness Support Table For ElectroPuls Test Instruments
- Loadframe Support Tables/Bases
- Support Table, Heavy Duty; For use with all Dual Column Table Top Models
- Base/Extension for Floor Models 4400, 5800 and 5900
- Static Hydraulic Universal Testing System Frame Accessories
- Dispositivos de teste de descolamento, atrito e perfuração
- Wood Test Fixture. Compression Parallel to Grain
- Medição e preparação de amostras
- Specimen Preparation Punching Machines
- Specimen Marking Punches
- Extra Punch Points , Set of Two
- Manual Gauge Point Punch, 8 in Gauge Length
- Manual Gauge Point Punch, 0.5 in Gauge Length
- Manual Gauge Point Punch, 1.4 in Gauge Length
- Manual Gauge Point Punch, Combination 1 in and 2 in Gauge Length
- Manual Gauge Point Punch, Combination 25 mm and 50 mm Gauge Length
- Specimen Measurement Devices
- Vertically Mounted Probe Automatic Measurement System
- Hand Held Automatic Caliper Measurement System with Carbide Tips
- 2850-007
- Micrometer, Outside, 0-25 mm (0-1 in) with Data Cable
- Micrometer, Outside, 25-50 mm (1-2 in) with Data Cable
- Caliper, Standard Jaw, 0-150 mm (0-6 in) w/Data Cable
- Caliper, Standard Jaw, 0-300 mm (0-12 in) w/Data Cable
- Caliper, Pointed Jaw, 0-150 mm (0-6 in) w/Data Cable
- Automatic Data Entry Interface for use with Partner
- Specimen Preparation Systems
- Placas de teste
- Catálogo de acessórios
- Dispositivos de teste de madeira
Testing Software
- BHI Pendulum
- Bluehill Central
- Bluehill Elements for Basic Materials Testing on 3400 Systems
- Bluehill Fracture
- Bluehill HV
- Bluehill Impact para Drop Towers
- Bluehill Universal
- Requisitos de computador do Bluehill Universal
- Últimos recursos no bluehill® universal
- Modelos de métodos em Bluehill Universal
- CrashSim
- DIC Replay
- LCF3 Software
- Console Software For Use With Instron 8800 Systems, ElectroPuls and ExtendUpgrades
- LCF 3 Low Cycle Fatigue Testing Software For Use With Instron 8800 Systems and Extend Upgrades
- CrashSim Office
- RS LabSite® modulogic
- WaveMatrix3 Dynamic Software
Testing Systems
- Sistemas de teste automatizados
- Estágio XY automatizado AT2
- Sistema de teste automatizado não robótico de 3 eixos AT3
- Sistema de teste automatizado robótico de 6 eixos AT6
- Sistema de teste de autoinjetor
- Sistema de teste de cobot CT6 para aplicações biomédicas
- ElectroPuls Automated XY Stage
- Multi-Station Test Frame for Simultaneously Mechanical Testing
- BI-7000 Servo Hydraulic Plug n Play Test System – The Nano
- BI-7020 Servo Hydraulic Medium Force Fatigue Test System
- BI-7030 Servo Hydraulic High Force Test System
- BI-7040 Servo Electric Test System
- BI-7050 Axial Torsion Test System
- BI-7060 Biaxial Test System
- BI-7080N Damper Noise Detection Test System
- BI-7080N Damper Noise Detection Test System
- BI-7080R Damper Test System for Railway Shock Absorbers
- BI-7090CS Damper Test System – Crank Operated
- Pesquisa em Construção Civil
- Crash Simulation Systems
- Damper Test Systems
- Piso Coluna Dupla 100 kN
- Sistemas de teste dinâmico e de fadiga
- Biaxial Cruciform Test Systems
- 8850 series Axial-Torsion System
- Low Strain Rate 8862 Servo-Electric Systems
- BI-7020/40
- BI-7020/40-Teste
- Sistema de Teste ElectroPuls® de 16 Estações
- ElectroPuls Systems
- High Temperature Fatigue
- General Purpose Hydraulic Fatigue
- Hydraulic Power Units
- Unidade de força hidráulica | Série 3621
- Controlador 8800MT / Upgrades de controlador
- Table Top Fatigue Testing Systems
- Floor standing Fatigue Testing Systems
- High Capacity Fatigue Testing Systems
- Stiffness Based Tuning
- Sistemas VHS de alta taxa de deformação
- Sistemas HDT & Vicat
- Alta Capacidade até 1000 kN
- Sistemas de testes de impacto, reologia e termomecânicos
- Sistemas de teste de impacto
- Máquina de ensaio de impacto por queda de peso
- Teste de impacto de flexão de 3 pontas
- Ensaios de componentes e peças acabadas
- Compressão após impacto
- Câmaras de temperatura baixa e alta
- Teste de perfuração
- Suportes, Suportes para TUPs e Insertos
- Método de ensaio de impacto a tração com um Drop Tower
- Ensaio de descolamento ao impacto por clivagem (wedge peel)
- Pêndulos
- Lab Health Check
- Out of Production Systems
- Acessórios do sistema de teste
- Sistemas fora de produção – dinâmicos
- Eletromecânico
- HDT & Vicat
- Medição e preparação de amostras
- Software fora de produção
- STATIC HYDRAULIC
- Reômetros & testadores de fluxo de fusão
- Série 2300 até 50 kN
- Sistemas de ensayo universales industriales hasta 2000 kN
- Structural Durability
- Structural Durability Products
- Controller Labtronic® 8800ml
- Hydropuls® actuators
- Power Packs and Accessories
- Sensors
- Servo valves
- Test frames and fixtures
- Structural Durability Solutions
- Structural Durability and Crash Simulation Testing Machines
- Retrofits e Atualizações de Sistema
- Torsion Add-On 3.0
- Sistemas para Torção
- Máquinas de teste de torção da série MT MicroTorsion
- Sistemas de teste universal
- 3400 & 6800 Series Universal Testing System Retrofits
- 5900 Series Universal Testing System Retrofits
- Custom Solutions
- Comparativo de Features | Série 3400 para Série 6800
- Sistemas de Ensaio Universais Industriais até 2000 kN
- 3380 Series Universal Testing Systems up to 100 kN (22,500 lbf) Force Capacity
- 5980 Series Floor Model Universal Testing Machine
- INDUSTRIAL SERIES (Translated to pt-br)
- Sistema de teste ISO 80369
- Sistemas de ensaio universais até 300 kN
Resources
- Manuals
- Serial Number Locator
- 1130 Machines Serial Number Locator
- 3342 Machine Serial Number Locator
- 3345 Machine Serial Number Locator
- 3365 Machine Serial Number Locator
- 446X Machines Serial Number Locator
- 554X Machines Serial Number Locator
- 558X Machines Serial Number Locator
- 594X Machines Serial Number Locator
- 596X Machines Serial Number Locator
- 598X Machines Serial Number Locator
- 8801 Machine Serial Number Locator
- 8841 Machine Serial Number Locator
- 8872 Machine Serial Number Locator
- TT-TM Machines Serial Number Locator
Services
- Calibration of Materials Testing Systems
- Calibration and Verification
- Calibration Lab and Accreditations
- Extended Warranty
- Glosario de Organizaciones de Normalización
- Glossaire des Organismes de Normalisation
- Glossario di Organismi di Normazione
- Implementation Assistance
- Installation & Relocation
- Instron® Connect
- Manutenção Preventiva
- Repair Service and Parts
- Return Material Authorization (RMA) Request
- Serviços de movimentação e realocação de sistemas
- Strain and Extensometers
- Atualizações e upgrades de sistema e software
- Temperature Verification
- Thank You for Submitting a Return Material Authorization Request
- Types of Calibration and Verification
- Types of Calibrations
- Teste de Alinhamento
- Creep Calibration
- Calibração de Força
- Dureza
- Calibração de Impacto
- Calibrações de Medição de Fluidez, HDT Vicat e Reômetro Capilar
- Verificação de Velocidade e Deslocamento
- Calibração de Deformação
- Calibração de Temperatura
- Updating or Upgrading Your Instron System and Software
Training
- Classroom Training
- Classroom Training Courses
- Courses
- Bluehill® Universal Advanced Test Method Development
- Bluehill® Universal Introduction to Test Method Development
- Bluehill® Universal TestProfiler Method Development
- Introduction to Static Materials Testing
- eLearning online
- Introdução básica aos testes de materiais
- Erros nos seus dados
- Reduzindo o Risco do Operador em Sistemas Electropuls
- Reduzindo o risco do operador em sistemas eletromecânicos
- Reduzindo o risco do operador em sistemas servo-hidráulicos
- O essencial dos testes biomédicos
- Onsite Training at Your Facility
- Regional Training
- Secrets of Reliable Testing
- Training FAQs
- Virtual Training
ASTM
- ASTM A370, ISO 6892-1, ISO 3183 e API5L: ensaio de tração de tubos e tubulações
- ASTM A370: Mechanical Testing of Steel Products
- ASTM A370, A416, ISO 15630 Tensile Testing of Multi-Wire Strand for Prestressed Concrete
- Gripping Solutions for Tensile Testing to ASTM E8, A370, A48, and GOST 1497-1
- ASTM A615 – Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement
- ASTM A746 Specification for Ductile Iron Gravity Sewer Pipe
- Teste de torção de fio ASTM A938 / ISO 7800
- ASTM C109
- ASTM C1550 Flexural Toughness of Fiber Reinforced Concrete
- Flex Testing of Fiber Reinforced Concrete to ASTM C1609-10
- ASTM C170 Compressive Strength of Dimension Stone
- ASTM C297 – Tensile Strength Composite Sandwich Constructions
- ASTM C365
- ASTM C39
- ASTM C633 Adhesion or Cohesion Strength of Thermal Spray Coatings
- ASTM C78 Flexural Strength of Concrete Beams
- ASTM C880 Flexural Strength of Dimension Stone
- ASTM C99 Modulus of Rupture of Dimension Stone
- ASTM D1004 Resistência ao rasgo (rasgo de Graves) de filmes ou folhas de plástico
- Propriedades de tração ASTM D1708 de plásticos usando corpos de prova microtensionados
- ASTM D1002
- ASTM D1037
- ASTM D1238
- ASTM D1238 – Testing High Fluidity Samples with a Piston Holding Device
- ASTM D1335
- ASTM D1414
- ASTM D1525 Determination of Vicat Softening Temperature of Plastics
- ASTM D1621
- ASTM D1876
- ASTM D1894
- ASTM D2256
- ASTM D2261
- ASTM D2444 Impact Resistance of Plastic Pipe and Fittings
- ASTM D256: Izod Impact on Carbon/PPS Composites Made from Recycled Carbon Fiber
- ASTM D256 Impact Strength of 3D Printing Peek
- ASTM D2844 AASHTO T190 CTM 301: ensaio de exsudação de umidade em solos compactados
- ASTM D3039 Tensile Properties of Polymer Matrix Composites
- ASTM D3163
- ASTM D3330
- ASTM D3364 Flow Rates for Poly Vinyl Chloride
- ASTM D3410
- ASTM D3763 High-Speed Puncture Properties of Plastics
- ASTM D3822 Tensile Properties of Textile Fibers
- ASTM D3835: Extrusion of neat and carbon reinforced polyether ether ketone (PEEK)
- ASTM D3846 In-Plane Shear Strength of Reinforced Plastics
- ASTM D4018
- ASTM D412
- ASTM D413 Rubber Property-Adhesion to Flexible Substrate
- ASTM D429 Rubber Property – Adhesion to Rigid Substrates
- ASTM D4632
- ASTM D5034
- ASTM D5035
- ASTM D5587 Tecidos com resistência ao rasgo pelo procedimento trapezoidal
- ASTM D575-91
- ASTM D5766
- ASTM D5961
- ASTM D6110 Determination of Charpy Impact Properties
- ASTM D6272 Flexural Properties of Plastics and Electrical Insulating Materials
- ASTM D638
- ASTM D6484
- ASTM D6641
- ASTM D695
- ASTM D7136/D7136M-05 Measuring Damage Resistance of Composite to Impact Event
- ASTM D7137
- ASTM D7192 High Speed Puncture Properties of Plastic Film
- ASTM D7269 Testing Aramid Cords: The Proper Grip
- ASTM D7860
- ASTM D882
- ASTM D885 Industrial Filament Yarns Made from Manufactured Organic-Based Fibers
- ASTM D903
- Wood Shear Testing
- Fire Resistant Steel: High-temp testing related to ASTM E119
- ASTM E1820
- ASTM E190
- ASTM E208 Drop Weight Test for Nil-Ductility Temperature of Ferritic Steel
- ASTM E21
- ASTM E23 Charpy Impact Testing Sub-Size Specimens
- ASTM E290
- ASTM E345
- ASTM E399
- ASTM F1306
- ASTM F1614 Impulse and Fatigue of Athletic Footwear Using Energy Control
- ASTM F1717
- ASTM F2077
- ASTM F2193
- ASTM F2256 Strength Properties of Tissue Adhesives by T-Peel Testing
- ASTM F2267
- ASTM F2346 Characterization and Fatigue Testing of Spinal Intervertebral Disc Prostheses
- ASTM F2412 – Impact Resistance – Safety Shoes
- ASTM F2458 Wound Closure Strength of Tissue Adhesives and Sealants
- Ensaio de tração ASTM F2516 de materiais de nitinol
- ASTM F2606
- ASTM F382 Flexural Fatigue Testing Metallic Bone Plates
- ASTM F384 Metallic Angled Orthopaedic Fracture Fixation Devices
- Ensaio ASTM F606 de fixadores, arruelas e rebites
- ASTM F88 Seal Strength of Flexible Barrier Materials
- Bone Screw Testing
- ASTM F3014
- Métodos de ensaio ASTM F543 para parafusos ósseos medicinais metálicos
- ASTM F2150 Testing Polymer Hydrogels
- ASTM D3574
- ASTM D624 Teste de resistência ao rasgo de borracha e elastômeros
- ASTM D790
- Ensaio de tração ASTM E8 de materiais metálicos
ISO
- ASTM A370, ISO 6892-1, ISO 3183 e API5L: ensaio de tração de tubos e tubulações
- Teste de torção de fio ASTM A938 / ISO 7800
- ISO 101132006
- Tensile Strain Hardening Exponent (n)
- ISO 10310 Non-Contact extensometry for Geosynthetics
- ISO 10555 Tensile Testing of Intravascular Catheters
- ISO 11040
- ISO 11193
- ISO 1133 Melt Mass-Flow Rate and Melt Volume-Flow Rate Thermoplastics
- ISO 1133-2 and ASTM D1238: when Load Cell ensures Repeatability of Results.
- ISO 11339
- ISO 11343 Determination of Adhesive Bond Strength Under Impact (wedge-peel test)
- ISO 11443, ASTM D3835 Determination of Properties of Polymeric Materials with a Capillary Rheometer
- ISO 11443 and ASTM D3835 tests to study Polymer Degradation
- ISO 11443 – Rheology of Heat-Curing Elastomers/Silicone at Room Temperature
- ISO 11443 Fluidity of Plastics Using Capillary and Slit Die Rheometers
- ISO 11443 Research, Design and Quality Assurance for Injection Moulding
- ISO 11443 – Rheology of low viscosity fluid for spray application
- ISO 11443 Extrudate Swelling
- ISO 11608 Testing Needle-Based Injection Systems
- ISO 11897 Thermoplastic Flexible Film Packaging, Tear Propagation Edge Folds
- ISO 12111 & ASTM E2368
- ISO 13001 and ASTM D3479 Improving Throughput in Composites Fatigue Tests
- ISO 13934-1
- ISO 13937-2 Tear Properties of Fabrics
- ISO 13937-3 Tear Properties of Fabrics
- ISO 13937-4 Propriedades de rasgo de tecidos – Amostras em forma de língua
- ISO 14125 Flexural Properties of Fiber-Reinforced Plastic Composites
- ISO 14126 In-Plane Compressive Properties of Fiber-Reinforced Plastic Composites
- ISO 14130 Determination of Apparent Interlaminar Shear Strength by Short-Beam Method
- ISO 1421:1998 Determination of Tensile Strength and Elongation at Break
- Tensile Strength of Basalt Fiber Reinforced Plastic (BFRP) Rebar
- ISO 14801
- ISO 14879
- Iso 15630 1
- ISO 16402 Flexural Testing of Acrylic Resin Cements Used in Orthopaedics
- ISO 17744 Determination of specific volume as a function of temperature and pressure (pvT diagram)
- ISO 179-2 Determination of Charpy Impact Properties – Instrumented
- ISO 1798 Tensile Strength Flexible Cellular Polymeric Materials
- ISO 180 Determination of Izod Impact Strength
- ISO 18489
- ISO 1926 Rigid Cellular Plastics Tensile Properties
- ISO 2062 Single-end Breaking Force and Elongation at Break of Yarns from Packages
- ISO 20795-1 and 20795-2 Flexure Test of Base Polymers
- ISO 2411 Coating Adhesion Rubber-Coated Plastics-Coated Fabrics
- ISO 306 Determination of Vicat Softening Temperature (VST)
- ISO 3133, ISO 3349, & ASTM D143
- ISO 3183 Fastener Double Shear Testing
- ISO 34-1
- ISO 36
- ISO 37
- ISO 4587
- ISO 527-2
- ISO 527-3
- ISO 527-4
- ISO 604 Propriedades de compressão de plásticos
- ISO 6383-1 Tear Resistance Plastic Film and Sheeting
- ISO 6603-2 Impact Resistance of Composite Materials – Nautical Applications
- ISO 6603-2 Puncture Impact Behavior of Rigid Plastics
- ISO 6603 – ASTM D3763: Quick impact at low temperature
- ISO 6872 Flexural Strength Testing of Dental Ceramics
- ISO 6892
- ISO 6892-2
- ISO 7206-4, 7206-6 and 7206-8
- ISO 75 and ISO 306: HDT and VST Tests on High Temperature Polymers
- ISO 7886-1
- Conectores de pequeno diâmetro ISO 80369 para líquidos e gases em aplicações de saúde
- ISO 8067 Flexible Cellular Polymeric Materials Tear Strength
- ISO 813 Adhesion Strength of Rubber to Rigid Substrates
- ISO 8256 Tensile Impact Tests on Playing Cards (PVC)
- Coeficiente de Friction ISO 8295 para filme plástico e chapas
- ISO 844 Rigid Cellular Plastics Compression Properties
- ISO 898-1
- ISO 9073-4 Tear Resistance Nonwovens
- ISO/TS 11405 Tensile Adhesion and Bond Strength of Dental Materials and Adhesives
- Resposta de tensão de cisalhamento/deformação de cisalhamento no plano ISO 14129
- ISO 178
Outros padrões
- AASHTO T190
- AITM Airbus Test Method for Determination of Compression Strength After Impact
- ANSI/AWS B4.0
- ASTM A370, ISO 6892-1, ISO 3183 e API5L: ensaio de tração de tubos e tubulações
- Axial Torsion Fatigue Testing
- Ball Indent Test Fixture
- Blister Pack Testing
- BSS 7260 Post-Impact Compressive Strength of Composite Laminates
- BS EN 319 Perpendicular Tensile Strength of Particleboards and Fiberboards
- Rheological tests on cap liners manufactured for plastic bottle caps
- Fatigue Testing of Compressor Valves
- Fatigue Testing of Computer Keyboards
- Multi-Axial Stress States Cruciform Specimens
- Shear Adhesion Strength Testing Dental Materials and Adhesives
- Impact Performance of Polycrystalline Diamond Cutters
- Drill Bit Tips
- Durability and Fatigue Testing of Elastomeric Materials and Components
- Spring Simulation with the ElectroPuls
- Electro-Thermal Mechanical Testing
- EN12089 – Determination of bending behaviour of Thermal Insulation Products.
- EN12090 – Determination of shear behaviour of Thermal Insulation Products.
- EN 12242
- EN 14477 Puncture Resistance of Flexible Packaging Material
- EN 14509 Shear Strength and Shear Modulus Roofing and Cladding Sandwich Panels
- EN 1465
- EN 1719
- EN 2561:1995 Carbon Fiber Reinforced Plastics — Unidirectional Laminates — Tensile Test Parallel to the Fiber Direction
- EN 2597
- EN 50086-2-4 Conduit Systems, Cable Management Underground
- EN 826 –Determination of compression behaviour of Thermal Insulation Products
- EN 868-5
- EN12430 Point Compression of Thermal Insulation
- Seletor de massa manual do plastômetro de extrusão
- Dynamic Fatigue Testing Femoral Nails
- High Velocity Three-Point Bending Test – Fiber Cement Materials
- Fatigue Testing of Finger Implants
- FTM2
- High Strain Rate Testing Metals
- High-speed impact testing on dashboards
- IS 1608
- EN 1939 Peel Adhesion Self Adhesive Tapes
- ISO 29862 / EN 1939 Self-Adhesive Tapes: Determination of Peel Adhesion Properties
- JEDEC JESD22B113
- Edgewise Drop Impact on Liquid Crystal Display (LCD) glass panels
- Low Force Dynamic Fatigue Testing of Tissues and Biomaterials
- In Vitro Microindentation of Bone to Determine Mechanical Properties
- MIL-STD-883
- NADCAP Alignment Standards
- NASM 1312-13 Fastener Double Shear Testing
- NIJ 0115.00 Stab Proof Vest For Body Armor
- Pill Crush Testing
- AC133 Rebar Coupler Test of Mechanical Connector Systems
- Residual Seal Force
- Impact Performance of Roofing Tiles
- Impact Performance of Safety Helmets
- Shock Absorbers
- Impact Resistance of Plastic Shotgun Shell Wadding
- Dynamic Investigation on the Influence of Inflation Pressure in Sports Balls
- Stent Materials
- Surgical Sutures
- Syringe Needle Testing
- TAPPI
- Lower Force Dynamic Fatigue Testing Plastics
- Fatigue and Fracture Testing of Tire Reinforcement Wire
Automotive
- Chassis
- Bumper Impact Testing
- Chassis and Body High Strain Rate Testing
- Composite Laminates Compression After Impact Testing
- Composite Laminates Tensile Testing
- Crash Simulation
- Exhaust Line Durability Test
- Exhaust Mount Fatigue Testing
- Fatigue Testing
- Full Vehicle Testing
- Road Simulation System
- Sheet Metal Bend Testing
- Sheet Metal Tensile Testing
- Structural Durability
- Drivetrain
- Axle Test System
- Clutch Durability Testing
- Drive Shaft Durability Testing
- Drive Shaft Torsion Testing
- Shock Absorbers Impact Test
- Electronics
- Bend Test on PCB
- Button and Switch Compression Testing
- Display Panel Testing
- Electrical Wire and Insulation Tensile Testing
- Terminal Strength Test
- Engine
- Crankshaft Torsional Fatigue Testing
- Internal Combustion Fatigue Testing
- Non-ambient Metals Tensile Testing
- Non-ambient Plastics Tensile Testing
- Interior
- Dashboard Drop Weight Impact
- HDT and Vicat Testing
- Headliner Peel Testing
- In Situ Testing
- Knobs and Buttons Tension Torsion Testing
- Plastics Tensile Testing
- Rigid Plastics Bend Testing
- Seating Foam Compression Testing
- Textiles Testing
- Joining
- Safety Systems
- Wheel and Tire
Biomedical Testing
- 21 CFR Part 11
- Biomaterials
- Bioadhesives Peel Testing
- Hard Tissue Testing
- Hydrogel Tensile Testing
- Impact Tests On Orthopedic Implants
- Impact Performance of Pharmaceutical Tablets
- Soft Tissue Testing
- Tensile Testing Polymeric Membranes
- Tissue Adhesives Testing Using a Variable Angle Peel Fixture
- Dental
- Drug Delivery Device and Container Testing
- Guide to PPE Testing
- Implantable Devices
- Contact Lens Testing
- Evaluation of Radial Forces from Embolic Filters
- Heart Pacemaker Testing
- Ocular Implant Testing
- Radial Force Evaluation of Stent Grafts
- Stent Testing
- Medical Consumables
- On Body Delivery Systems
- Orthopedics
Electronics
- Electronic Devices
- Bend Testing of Cables and Wires
- Bend Testing of Devices
- Bend Testing of Screens
- Button and Switch Tactility Testing
- Compression Testing of Batteries
- Headphones Compression Testing
- Insert and Extract Testing on Devices
- Multi-Point Compression Testing of Screens
- Peel Testing of Screens
- Fine Wires
- General Purpose Applications
- Lap Shear Test
- Peel Testing Photovoltaic or Solar Cells
- Pin Pull Test of Connectors
- Tension Testing of Cables and Wires
- Keypad
- Microelectronics
- Bend Test of Electronic Packages
- Bend Testing of Printed Circuit Boards
- Compression Testing of IC Packages
- Die Shear Testing of Electronic Packages
- Lead Frame and Wire Bond Pull Test
- Solder Ball Compression Test
- Stud Pull Test for Electronic Packages
- Tensile Testing of Copper Clad Laminates (CCL)
- Torsion Testing of Flexible Circuits and Microelectronic Components
Blog
- Como conectar transdutores a sistemas Instron: quatro métodos
- Transformação da USP 381 e suas substituições
- O seu lab de testes está pronto para o Windows 11?
- Destaque farmacêutico: expandindo a capacidade de teste para dispositivos de administração de medicamentos
- Reducing Variability in High Temperature Materials Testing
- High vs. Low Flow Materials: 4 Testing Solutions to Enhance Reliability and Accuracy of Your Results
- Bluehill Impact para Pendulum
- How to Choose the Right Mechanical Testing Automation for Your Biomedical Manufacturing Lab
- Mechanical Testing in the Biomedical Industry
- 5 Steps to Effective Mechanical Testing Automation for Biomedical Labs in CDMOs
- How Automation Can Improve Plastics Testing
- Ductile to Brittle Transition Temperature
- Top 5 Considerations When Selecting a Pendulum Impact Testing Machine
- NLR Unveils Instron’s E20000 All-Electric Fatigue Machine
- How to Achieve More Repeatable Test Results in 3D Printing Applications
- The ABCs of XY Stage Adhesive Tack Testing
- Melt Flow Index Tester Maintenance: top tips to optimize repeatability and accuracy
- Top Benefits of Semi-Automation for Materials Testing
- How To Decrease Variability in Test Results with Specimen Protect
- I Hope This Tree Isn’t Afraid of Needles!
- Heat Deflection Temperature and Vicat Softening Temperature Testing
- Definitive Guide to Syringe Testing per ISO 11040 & ISO 7886
- Drop Weight Impact Test: Top Tips for Accurate Results
- Alignment Tips for the AutoX750 Extensometer
- Why is Pendulum Impact Testing Important in Research
- How to Perform a CAI Test More Accurately and Safely
- Using a 3-Jaw Chuck for Materials Testing
- How to measure the Melt Flow Index of recycled and biodegradable plastics
- Mechanical Testing of Additive Manufactured Components
- Falling weight impact testing for simulation precision: meet Lamborghini
- Manual or Automatic Melt Flow Index Testers
- 5 steps to selecting hammers for your pendulum impact testing machine
- How is an Impact Drop Tower used in Testing Automotive Parts
- Wedge Peel Impact Test on Adhesives
- How to test carbon fiber impact strength
- Pendulum Impact Testing Machine or Drop Tower
- Product Spotlight: Component Test Plate
- Origami-based structures under Impact load
- Drop Tower Tensile Impact Testing for High Strain Rate Measurements
- How to Test the HDT of 3D Printing Materials
- How To Investigate Dynamic Failures of Materials
- Materials and Applications Solutions for the Biomedical, Plastics, and Elastomer Industries
- Will Product Failure Put Your Company at Risk?
- Compression Testing of Concrete Blocks with Recycled Plastic
- Alignment for Materials Testing Webinar
- Braided Rope Tensile Testing
- Traceability Webinar + Q&A
- Biaxial Testing of Medical Devices
- Biomedical Case Study | Ghent University
- Bluehill® Universal Software: Top 5 FAQs
- When You Don’t Take Advantage of Software Updates
- O que “Software Amigável ao Toque” Realmente Significa?
- Micro Three-Point Bend Testing for Microelectronics
- Own Your Data and Results: Export Files, Import to LIMS
- How Important is Calibrating Materials Testing Systems?
- Traceability: What is it, and Why is it Important in Testing of Materials?
- Growth of ITW Young Professionals Network in Europe
- Gage Repeatability and Reliability: Ensuring Accurate Test Results for Measurement Systems
- Metals Market Reacts to Material Trends
- Plastics Analysis for Automotive Applications
- Why Measure Strain Optically?
- Why Measure Strain Optically?
- Opticle Strain Article
- What Value Does ISO 9001 Add?
- Custom Fixture for Plastic Drinkware
- Olympic Edge: Optimizing Athletic Equipment
- Custom Solution for Testing in Extreme Environments
- Non-Contacting Strain Measurement Techniques in Fatigue Testing of Polymer Matrix Composites
- What is a Texture Analyzer?
- Penn State Students Receive a Behind-the-Scenes Tour
- Small Transitions to Automation Make a Big Impact
- Increase Efficiency Without Sacrificing Safety
- Overcoming Sheet Metal Testing Challenges
- Instron Supports MassChallenge Startups
- Step-by-Step Tutorial on Using Melt Flow Tester to ISO 1133 and ASTM D1238
- Importance of Medical Packaging Standards
- An Introduction to Digital Image Correlation
- The Benefits of Automated Materials Testing
- Steel Reinforcement Bar: A Tensile Testing Guide
- Simulating Body Temperature When Testing Biomedical Devices and Materials
- Building a Business Case for Modernisation: An Interview with Nick Shrubsall
- Overcoming Challenges of Rebar Testing
- Digital Image Correlation for Measuring Full-field Strain and Displacement
- Have You Thought About The Implications If The Material for Airbags Responds Poorly?
- AZoM Interview: 3 Challenges of Plastics Testing
- Contrasting Composites vs. Metals in Aerospace
- Future Engineers Taking a Hands-on Approach at WPI Using Instron Equipment
- Supporting Science, Technology, Engineering, and Mathematics (STEM) Programs
- The MPX Series of Motorized Pendulum Impact Testers: An Interview with Matthew Spiret
- Is This the Next Generation of Smartphone Cases?
- Tips and Tricks for Packaging Testing
- Helping to Standardize High-Rate Testing of Composites
- Question From a Customer: Air Bubbles in Extrudate
- Challenges of Rigorous Demands
- Evaluating the Quality of High Performance Plastics Molding
- How to Address Challenges in QC Medical Device Testing
- Is Design Validation Slowing Down Your Time To Market?
- Stress Control and Yielding Material
- How to Test Lap-Shear Specimens
- Understanding Melt Flow Testing and Its Importance
- Helping to Provide the Good Housekeeping Seal of Approval
- Testing a Student-Made Off-Road Vehicle
- Preloading, and How It Affects Your Mechanical Test
- Automated XY Stage System Preventing Shattered Glass and Inaccurate Data
- Oyster Glue Inspiring Stronger Adhesives
- High Frequency Testing of Nitinol Wire
- Consumer Reports Uses Instron for Bend Testing Smartphone
- Quick Tips for Balancing Load Cells
- What is the Best Way to Grip Thin-walled Steel Tubes for Tension Testing?
- WPI Students Test ACL Graft Pretension Methods
- Extensometer Slippage
- Efficiency of Continuously Increasing Load During Tests
- How Do You Prepare Your Specimens?
- Looking for Ways to Keep Bent Test Specimens Securely Aligned?
- Challenges of Rebar Testing
- Composites on the Move
- Reducing Variablity in Plastics Testing
- Plastics Testing: Increasing Laboratory Efficiency & Throughput
- Does a Charpy or an Izod Impact Test Replicate any Real-Life Scenarios?
- Reminder to Not Let Your Standards Slip
- Quick Tip: Determining if a Specimen is Too Heavy for Your Test
- Backward Strain at Yield — Discontinuous Yielding/YPE Material
- Understanding Changes to Key Plastics Testing Standards
- Wedge Action Grips: Which is Moving?
- The Truth About Strain Gauge Load Cells vs. Pressure Transducers
- Thermoset and Thermoplastic Composites … What’s the Difference?
- Testing United States Bridges at Columbia University
- 4-Point Bend Testing of Carbon Fiber
- Changes Pipe & Tube Manufacturers and Suppliers Should Know
- Charpy Impact Testing: Minimizing Hammer Changes
- Software Module Increases Test Frequency for Fatigue Testing of Composites and Polymers
- What is The Difference Between Proportional and Non-proportional Clamping Force?
- What is the Best Way to Check the Functionality of my ElectroPuls™ Load Cell?
- What is N-value?
- Metals Tensile Testing Standards: ISO 6892-1, ASTM E8/8M for Strain Control
- Testing Metals to ASTM E8 with an Automatic Contacting Extensometer
- Energy-Controlled Impulse Testing of Shoes
- Question From a Customer: How to Report Strain at Break Following ASTM D638
- What is Digital Image Correlation (DIC) and How Can It Help Me?
- What is Digital Image Correlation (DIC) and How Can It Help Me?
- Calling all Hockey Players: How Safe & Durable is Your Equipment?
- Challenges with Steel
- Question from a Customer: What tup do I use on my 1,800 J (1,330 ft-lb) drop tower?
- Carbon Fiber Hits the Road
- Poisson’s Ratio Testing With A Biaxial Extensometer
- Simulating a Spring with the ElectroPuls
- Upper Yield Calculations—Discontinuous Yielding/YPE Material
- What Does Load Measurement Accuracy of 0.5% of Reading Down to 1/100th, 1/500th, 1/1000th of a Load Cell’s Capacity Imply?
- Industry Insights Series with David Fry
- Equipment Considerations for a Well-aligned Test
- Question from a Customer- Bagley Correction
- Google for Test Results
- A New Long-Term Bypass Solution
- Question from a Customer
- What is Stress Whitening, and How Can it Impact Your Test
- Instron at the World’s Largest Wind Turbine Testing Facility
- Analysis at Every Stage of the Plastics Lifecycle
- Instron Supporting Britain’s Economic Growth
- Question From a Customer: Why is Strain Rate Important?
- Materials in Space
- Industry Insights Series with Marco Bronzoni
- Simulating a Physiological Environment
- Tips on Using Environmental Chambers and Furnaces
- What is R-Value?
- Stronger than Steel and more Elastic than Rubber
- Bamboo Bikes – A “Growth” Industry
- Composites Question from a Customer
- Strain Measurement When Testing Composites
- Testing Uncovers Titanic Mystery
- Fatigue Testing of Stents and Stent Materials
- Industry Update: Mechanical Testing of Stents and Stent Materials
- Quick Tip on Gripping
- Hobas Pipe USA Installs Giant Custom-Built Instron Frame
- Selecting a Pressure Transducer for Your Capillary Rheometer
- Question from a Customer
- A Very Deep Investment
- Quick Gripping Tips
- Engaging with Our Readers: Survey Findings
- Damage Tolerance: Is it Important to You?
- Free Whitepaper on Mechanical Testing of Medical Implants
- 30 Years and Counting
- Predicting the Properties of Virtual Materials
- Question from a Customer
- Grip it Right
- Protecting Mobile Devices from Impact Damage
- Creation of a New Generation of Testing Instruments: Part 2
- Creation of a New Generation of Testing Instruments
- Race Ahead of Strain Measurements
- What is the Impact on an Airplane Wing?
- Sometimes You Never Know Where This Job Will Take You
- Tennis and Composites – What’s the Connection?
Case Studies
- A Comparative Study of Test Result Variability
- AMRC
- ANH Refractories
- Beijing Naton Medical Group
- Boston University | KABlab
- Unique Dynamic and Static Testing Function of ElectroPuls
- Ghent University
- Ghent University2
- INNOPROOF
- Kiguchi Technics
- LOLIWARE
- Polyset Company
- PRA
- Primo Medical Group
- Realtest Case Study
- Samyang
- Siemens combine Machine Learning with ElectroPuls
- Synoste
- TPRC
- Tubular Services
- TÜV SÜD Case Study
- UCL Low Force Testing with ElectroPuls
- University Research
- Vamp Tech
- Wentworth Institute of Technology
- Whitehouse Laboratories
- ZF Shanghai Case Study
News
- Register Now for the 2025 Metals Testing Showcase
- 25 Ways to Test a Syringe: On-Demand Webinar
- Lançamento da plataforma de software Bluehill Central 2
- Dortmund Biomedical Workshop
- Instron Exhibiting at CAMX 2024
- Instron em exposição na InterBattery 2025
- Instron Exhibiting at JEC World 2024
- Instron Exhibiting at MDM West 2024
- Instron Exhibiting at NEPCON 2024
- Instron Exhibiting at NPE 2024 | The Plastics Show
- Instron Exhibiting at Prefilled Syringes West Coast 2024
- Instron Exhibiting at SAMPE 2024
- Instron Exhibiting at The Battery Show North America 2024
- Instron Exhibiting at The Battery Show Europe 2024
- Instron Introduces AverEdge32 for AVE 2
- Instron Introduces Bluehill Central Lab Management Software
- Instron Introduces New 3400 and 6800 Series Universal Testing Systems
- Instron apresenta novos sistemas de ensaio universais das séries 3400 e 6800 em capacidades de 100 kN e 300 kN
- Instron Introduces New Precision Specimen Loader for Thin Films and Foils
- Instron Introduces TrendTracker Module for Bluehill Central
- Instron lança sistema de teste universal modelo de mesa de 100 kN
- Instron Launches All-New Live Virtual Training Classes
- Instron lança o novo extensômetro de vídeo avançado AVE3
- Instron lança sistema de teste de autoinjetores de última geração
- Torsion Add-On 3.0 for Axial Test Systems
- Instron Releases New 9400 Series Drop Towers Featuring Bluehill® Impact Software
- Instron Releases New Bluehill® Impact Software
- Instron Releases Traceability Module in Bluehill Universal
- A Instron Service lança o Suporte Técnico Remoto Instron
- Instron Statement on Log4j Vulnerability
- Instron Supports Development of New Composites Test Standard
- Instron to provide free remote training opportunities for students and teachers impacted by COVID-19
- Introducing Instron Connect
- Migrate to newer Drop Weight Impact Testing technology to minimize risks
- Instron Introduces New 10-Year Mechanical Systems Warranty
- New AT3 Floor Model Automated Testing System
Glossary
- Actuator
- Anisotropic or Anisotropy
- Anvils
- Calibration
- Capillary Rheometer
- Capillary Rheometer Die
- CEAST: Compagnia Europea Apparecchi Scientifici Torino (CEAST)
- Compression Set
- Controller
- Creep
- Creep and Stress-Relaxation Test
- Creep Test
- Crosshead
- Dynamic Mechanical Analysis (DMA)
- Elastic Hysteresis
- Elastic Limit
- Elongation
- Extension
- Extensometer
- Fatigue
- Fatigue Test
- Fracture Toughness
- Gauge Length
- Definição de impacto Charpy
- Isotropic
- Izod (Impact)
- Izod (Impacto)
- Load
- Load Cell
- Load Frame
- Load String
- Materials Testing Machines
- Maximum (yield) Load (Impact)
- Melt Flow
- Modulus of Elasticity
- Modulus of Toughness
- Necking
- Offset Yield Strength
- Offset Yield Strength
- Poisson’s Ratio
- Precycling
- Pressure Transducer
- Prompted Test
- Proportional Limit
- Ramp
- Secant Modulus of Elasticity
- Shear Strength
- Specimen
- Proteção de espécimes
- Strain
- Stress
- Stress Relaxation
- Diagrama de tensão-deformação
- Resistência ao rasgo
- Resistência ao rasgo
- Tensile Impact Test with Pendulum Impact Tester
- Tensile Strength
- Time for Rupture
- Transducer
- True Stress
- Uncertainty of Measurement
- Ponto de rendimento
- Yield Strength
Videos
- 3-Jaw Chuck for Materials Testing
- 3500KPX | Static Hydraulic Universal Testing System
- 6 Benefits of Storing Testing Files in a Centralized Database
- 90° Pneumatic Peel Fixture: Testing Adhesion of Electrodes in Lithium-Ion Batteries
- About Instron: The Leading Force in Mechanical Testing
- Accessing Calibration Certificates & Service History: Quick Tips From Instron® Service
- Accuracy and Usable Range of Load Cells
- Advanced Hydraulic Wedge Action Grips
- Applications of HDT and Vicat Tests
- ASTM D1002: Lap Shear Testing of Adhesively Bonded Metals
- ASTM D1894 and ISO 8295: Coefficient of Friction on Plastic Film
- ASTM D3330: Test Method for Peel Adhesion of Pressure-Sensitive Tape
- ASTM D903: Peel or Stripping Strength of Adhesive Bonds
- ASTM F1614: Shock Attenuation Testing of Athletic Footwear
- ASTM F88
- AT2 Automated XY Stage: Configured for Plastic Extrudate Crush Testing
- AT2 Automated XY Stage: Throughput and Efficiency
- AT3 Automated Film Tensile Testing to ASTM D882
- AT3 Automated Testing System
- AT3 Automated Testing System: Configured for Elastomer Testing
- AT3 Automated Testing System: Configured for Foil Testing
- AT3 Automated Testing System: Configured for Medical Glove Testing
- AT3 Automated Testing System: Configured for Metals Tensile Testing
- AT3 Automated Testing System: Configured for Thin Film Testing
- AT6 Automated Testing System: Configured for Metals Tensile and Hardness Testing
- AT6 Automated Testing System: Configured for Non-Ambient Elastomer Testing
- Autoinjector Testing System: Simple Test Methods
- Autoinjector: Device Changeover and System Alignment
- Autoinjector Testing System: Root Cause Analysis
- Extend Your Warranty Agreement
- Automated Carousel Testing System
- AutoX750 Automatic Contacting Extensometer
- AVE 2 Dynamic: High Force Applications
- AVE 2 Dynamic: Low Force Applications
- AverEdge32™ | Advanced Averaging Transverse Strain Measurement for Sheet Metal
- Axial Clip-On Extensometer
- Bluehill 1, 2, and Lite: Your Software’s Next Steps
- Bluehill® 3 | Your Software’s Next Steps Webinar
- Bluehill® Central | Lab Management Software from Instron®
- Bluehill Impact Tup Calibration Alert for Drop Weight Impact Tester
- Busbar Terminal Weld Testing — For Electric Vehicle Batteries
- Charpy impact test
- Che cose un prova di trazione
- Compression After Impact with a Drop Weight Impact Testing Machine
- CT6 Cobot Configured for Auto-Injector Testing
- CT6 Cobot Configured for Syringe Testing
- CT6 Cobot Configured for Torsion Testing
- Curved Needle Test System | Penetration Testing to ASTM F3014-14
- Cylindrical Cell Weld Testing — For Electric Vehicle Batteries
- DCPD Measurement for Fracture Toughness and Crack Growth
- Downloading Bluehill Universal Updates: Quick Tips From Instron Service
- Drop-Through Load Cell Adapter for 6800 Series Retrofits
- Electrical Contact Testing on a Universal Testing Machine
- ElectroPuls® E20000
- Environmental Chambers for Non-Ambient Materials Testing: 3119-600 Series
- Expert Tips for Testing Electronics
- Force and Strain | What You Need To Know Webinar
- The Hidden Variables in Your Test Results
- High Volume Hot Tensile Testing | Dual Furnace Setup on 68FM-100
- How To Optimize Your Lab Management with Bluehill Central
- Inside Instron: Precision Manufacturing at Our Binghamton, NY Facility
- Instron 100 kN Table Models
- Instron 3400 & 6800 Series System Retrofits
- Instron® 68FM Universal Testing Systems: Advanced Performance for High-Force Testing
- Instron® AT3 | Configured for Flex Testing
- Instron® AT3 | Configured for Tensile Testing
- AVE 2 Non-Contacting Video Extensometer
- Extensômetro de Vídeo Avançado AVE3 da Instron
- Instron Connect
- Instron Connect Feature Highlights: SightCall
- Instron Connect InSkill: AI-Driven Troubleshooting Tool
- Instron Connect InSkill: Calibration Certs & Service History
- Instron Connect Portal: AI Troubleshooting Tool
- Instron Connect Portal: Calibration Certificates and Service History
- Instron Connect Portal: Creating an Account
- Instron Connect Portal: Downloading Software Updates
- Instron Connect Portal: Raising a Support Request
- Instron Connect Software: Bluehill 3 Screenshare
- Instron Connect Software: Bluehill Universal Screenshare
- Instron Connect Software: Calibration Reminders
- Instron Connect Software: Downloading Bluehill Universal Updates
- Instron® | CT6 Cobot With Universal Testing System
- Instron® | ElectroPuls® Automated XY Stage
- Instron® Hydraulic Dual Side Acting Grips
- Instron® | Máquinas de Teste de Impacto por Queda de Peso da Série 9400
- Instron® Professional Services | Do You Have an Instron Connect Agreement?
- Instron Professional Services: System Move and Relocation
- Instron Safety: How To Use a Tensile and Compression Testing System Safely
- Instron Training Center
- Autoinjector Testing System
- Intro to Composites Testing Standards and Methods
- Introducing TrendTracker for Bluehill Central Webinar
- Introduction to Instron Universal Testing Machines
- ISO 7886-1 Testing Sterile Hypodermic Syringes
- ISO 80369: Mechanical Testing of Luer Connectors
- Lab Management in Bluehill Central
- Long Travel XL Extensometer
- Materials Testing for Aerospace Applications
- Mechanical Testing of Additive Manufactured Materials & Components
- Melt Flow Index Testers
- MFi Series: The Importance of Deadweights
- Moving an Instron Dual Column Table Model Universal Testing System
- Moving an Instron Single Column Universal Testing System
- MPX Series Pendulum Impact Test System With Bluehill® Impact Software
- Multi-Station Test Frame for Simultaneous Mechanical Testing
- Named Transducers in Bluehill Universal
- Piggyback Load Cell Adapters
- Piggyback Load String Adapters
- Precision Specimen Loader for Thin Films and Foils
- Puncture Test Fixture: Testing Separator Film for Electric Vehicle Batteries
- Putting History to the Test
- Quick-Mount Load Cell Adapters
- Quick-Mount Load Cell Adapters
- Quick Tips for Testing: Active Zones in Bluehill Universal
- Quick Tips for Testing: Bluehill® Universal 4.42 Calculation Fail Icons
- Quick Tips for Testing: Cable Management on 3400 and 6800 Series Systems
- Quick Tips for Testing: Clean Your Grips to Avoid Slips
- Quick Tips for Testing: Graduating with Cylinders
- Receiving Your Instron Electromechanical Universal Testing System
- Reducing Operator Risk on ElectroPuls Systems | eLearning Course
- Reducing Operator Risk on Servohydraulic Systems | eLearning Course
- Requesting Tech Support Using Instron Connect: Quick Tips from Instron Service
- Residual Seal Force Testing with the AT2 Automated XY Stage
- Retrofitting and Modernizing Legacy Testing Equipment
- Revision History in Bluehill Universal
- Righting and Moving an Instron Floor Model Universal Testing System
- Ring and Pin Features of Instron® 2580 and 2530 Series Load Cells
- Specimen Alignment Device CP135054
- Specimen Protect: 6800 and 5900 Series Universal Testing Systems
- Tack Testing Fixture Testing the Adhesion of Electrodes
- Teams in Bluehill Central
- Tensile Grip Guide
- Tensile Testing of Thin Films to ASTM D882 / ISO 527-3
- Testing Insulin Delivery Devices
- The Definitive Guide to Metals Tensile Testing to ASTM E8 and ASTM A370
- The Definitive Guide to Syringe Testing Per ISO 11040 & ISO 7886
- TrendTracker for Bluehill Central Software
- TrendTracker Product Tour
- Understanding Strain Rate to ISO 6892-1 and ASTM E8
- WaveMatrix3: How to Easily Set Up Stress Channel Control Tests
- WaveMatrix3: How to Rapidly Manipulate Datasets to Regenerate Graphs
- Webinar: Control Charts and Statistics in Bluehill Central’s TrendTracker Module
- Webinar: How to Expand Your Testing Capabilities With Piggybacking
- Webinar: Introducing Bluehill® Central Software
- Webinar: Overcoming Mechanical Testing Challenges for EV Battery Material Development and Production
- Weld Testing Fixture: Prismatic Cell Weld Testing
- What Is a Universal Testing Machine/Tensile Testing Machine?
- What Is an Extensometer?
- What Is Bend Testing?
- What is Compression Testing?
- What Is Peel Testing?
- What Is Peel Testing?
- What is Tensile Testing?
- Why Is Preventative Maintenance Important?
- Why Use a Mechanical Tensioner to Secure Your Load Cell